{"id":4259,"date":"2026-06-03T12:42:06","date_gmt":"2026-06-03T04:42:06","guid":{"rendered":"https:\/\/trg.unhas.ac.id\/smsrg\/?p=4259"},"modified":"2026-08-19T06:02:33","modified_gmt":"2026-08-18T22:02:33","slug":"stronger-without-the-cover-rethinking-how-concrete-beams-are-reinforced","status":"publish","type":"post","link":"https:\/\/trg.unhas.ac.id\/smsrg\/stronger-without-the-cover-rethinking-how-concrete-beams-are-reinforced\/","title":{"rendered":"Stronger Without the Cover? Rethinking How Concrete Beams Are Reinforced"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">GOWA, Indonesia Jun 03 2026\/SMSRG\/ \u2013\u00a0Concrete cover is usually considered essential in reinforced concrete. It protects steel reinforcement from moisture, corrosion, and environmental damage. But what happens if a beam could be designed without conventional concrete cover while still maintaining\u2014or even improving\u2014its structural performance?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A study titled <strong>\u201c<em>Flexural Behaviour of GFRP Bar Reinforced Concrete Beam Without Cover Using GFRP Sheet as Shear Reinforcement<\/em>\u201d<\/strong>, published in the <strong><em>International Journal of Advanced Research in Engineering and Technology (IJARET)<\/em><\/strong> on <strong>19 June 2020<\/strong>, investigated this unconventional approach. The researchers replaced conventional steel reinforcement with corrosion-resistant Glass Fiber Reinforced Polymer (GFRP) bars and used GFRP sheets as shear reinforcement.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Why consider such a design? One major problem affecting reinforced concrete structures is corrosion. Steel reinforcement can corrode when moisture and aggressive substances reach it. As corrosion progresses, the steel loses cross-sectional area and the surrounding concrete can crack and spall. These problems can reduce both the flexural and shear performance of a beam.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">GFRP offers an interesting alternative because it is resistant to corrosion. The researchers therefore explored whether removing the concrete cover could increase the effective depth of the beam while using GFRP to maintain durability. The study compared beams reinforced with conventional steel, conventional GFRP bars, and GFRP bars without concrete cover combined with GFRP sheets as shear reinforcement. The beams were tested under four-point monotonic loading until failure.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"443\" src=\"https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-9-1024x443.png\" alt=\"\" class=\"wp-image-4260\" srcset=\"https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-9-1024x443.png 1024w, https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-9-300x130.png 300w, https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-9-768x332.png 768w, https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-9.png 1300w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The results were striking. The GFRP beam without concrete cover and with GFRP sheet shear reinforcement achieved a <strong>52.9% higher flexural load capacity than the conventional steel-reinforced beam<\/strong>. It also achieved a <strong>13.4% higher capacity than the conventional GFRP-reinforced beam<\/strong>. These results suggest that eliminating the concrete cover can increase the effective depth enough to provide a significant structural advantage under the tested conditions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The researchers also found that the special GFRP configuration had <strong>10.6% higher stiffness than the conventional GFRP beam<\/strong>. However, there was an important trade-off: its ductility was lower than that of the conventional reinforced concrete beam, partly because of its lower cross-sectional shear capacity. This reminds us that structural performance cannot be judged by strength alone. Strength, stiffness, ductility, and failure behavior must all be considered together.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Why does this matter for the future of infrastructure? Bridges, buildings, and other concrete structures increasingly need materials that can withstand harsh environments while requiring less maintenance. Corrosion-resistant GFRP reinforcement could help extend service life and reduce deterioration-related repairs when properly designed and applied.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This research supports <strong>Sustainable Development Goal 3 (SDG 3): Good Health and Well-Being<\/strong>, because durable and reliable structural systems contribute to safer buildings and infrastructure. It also supports <strong>Sustainable Development Goal 11 (SDG 11): Sustainable Cities and Communities<\/strong>, by exploring ways to create more durable infrastructure that can serve communities for longer periods with reduced vulnerability to corrosion.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The lesson is not that concrete cover is unnecessary in every structure. Instead, the research shows that innovative reinforcement systems can challenge traditional assumptions. With appropriate design, testing, and engineering judgment, GFRP may open new possibilities for creating durable concrete structures that are better prepared for the environmental challenges of tomorrow.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Reference:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">DOI: https:\/\/doi.org\/10.34218\/IJARET.11.6.2020.047<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Contact:<br>Prof. Rudy Djamaluddin<br>+62-811-4666-10<br>rudy0011@gmail.com<\/p>\n","protected":false},"excerpt":{"rendered":"<p>GOWA, Indonesia Jun 03 2026\/SMSRG\/ \u2013\u00a0Concrete cover is usually considered essential in reinforced concrete. It protects steel reinforcement from moisture, corrosion, and environmental damage. But what happens if a beam could be designed without conventional concrete cover while still maintaining\u2014or even improving\u2014its structural performance? A study titled \u201cFlexural Behaviour of GFRP Bar Reinforced Concrete Beam [&hellip;]<\/p>\n","protected":false},"author":74,"featured_media":4260,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","_themeisle_gutenberg_block_has_review":false,"footnotes":""},"categories":[50],"tags":[43,35],"class_list":["post-4259","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-research-project","tag-sdg11","tag-sdg3"],"acf":[],"uagb_featured_image_src":{"full":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-9.png",1300,562,false],"thumbnail":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-9-150x150.png",150,150,true],"medium":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-9-300x130.png",300,130,true],"medium_large":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-9-768x332.png",768,332,true],"large":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-9-1024x443.png",1024,443,true],"1536x1536":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-9.png",1300,562,false],"2048x2048":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-9.png",1300,562,false]},"uagb_author_info":{"display_name":"adminsmsrg","author_link":"https:\/\/trg.unhas.ac.id\/smsrg\/author\/adminsmsrg\/"},"uagb_comment_info":0,"uagb_excerpt":"GOWA, Indonesia Jun 03 2026\/SMSRG\/ \u2013\u00a0Concrete cover is usually considered essential in reinforced concrete. It protects steel reinforcement from moisture, corrosion, and environmental damage. But what happens if a beam could be designed without conventional concrete cover while still maintaining\u2014or even improving\u2014its structural performance? A study titled \u201cFlexural Behaviour of GFRP Bar Reinforced Concrete Beam&hellip;","rttpg_featured_image_url":{"full":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-9.png",1300,562,false],"landscape":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-9.png",1300,562,false],"portraits":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-9.png",1300,562,false],"thumbnail":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-9-150x150.png",150,150,true],"medium":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-9-300x130.png",300,130,true],"large":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-9-1024x443.png",1024,443,true],"1536x1536":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-9.png",1300,562,false],"2048x2048":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-9.png",1300,562,false]},"rttpg_author":{"display_name":"adminsmsrg","author_link":"https:\/\/trg.unhas.ac.id\/smsrg\/author\/adminsmsrg\/"},"rttpg_comment":0,"rttpg_category":"<a href=\"https:\/\/trg.unhas.ac.id\/smsrg\/category\/research-project\/\" rel=\"category tag\">Research Project<\/a>","rttpg_excerpt":"GOWA, Indonesia Jun 03 2026\/SMSRG\/ \u2013\u00a0Concrete cover is usually considered essential in reinforced concrete. It protects steel reinforcement from moisture, corrosion, and environmental damage. But what happens if a beam could be designed without conventional concrete cover while still maintaining\u2014or even improving\u2014its structural performance? A study titled \u201cFlexural Behaviour of GFRP Bar Reinforced Concrete Beam&hellip;","_links":{"self":[{"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/posts\/4259","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/users\/74"}],"replies":[{"embeddable":true,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/comments?post=4259"}],"version-history":[{"count":2,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/posts\/4259\/revisions"}],"predecessor-version":[{"id":4295,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/posts\/4259\/revisions\/4295"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/media\/4260"}],"wp:attachment":[{"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/media?parent=4259"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/categories?post=4259"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/tags?post=4259"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}