{"id":4205,"date":"2026-06-03T23:25:07","date_gmt":"2026-06-03T15:25:07","guid":{"rendered":"https:\/\/trg.unhas.ac.id\/smsrg\/?p=4205"},"modified":"2026-08-19T06:00:07","modified_gmt":"2026-08-18T22:00:07","slug":"the-hidden-connection-that-keeps-concrete-structures-strong","status":"publish","type":"post","link":"https:\/\/trg.unhas.ac.id\/smsrg\/the-hidden-connection-that-keeps-concrete-structures-strong\/","title":{"rendered":"The Hidden Connection That Keeps Concrete Structures Strong"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">GOWA, Indonesia Jun 03 2026\/SMSRG\/ \u2013\u00a0When we look at a reinforced concrete beam, we usually notice the concrete and the reinforcement bars. But there is an invisible connection between them that is just as important: <strong>bond<\/strong>. Bond allows forces to move from the concrete into the reinforcement and back again. Without sufficient bond, a reinforcement bar may slip inside the concrete, preventing the structure from behaving as intended. This becomes particularly important when conventional steel reinforcement is replaced by Glass Fiber Reinforced Polymer (GFRP) bars.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A study titled <strong>\u201c<em>Effect of Bonding Area on Bond Stress Behavior of GFRP Bars in Concrete<\/em>\u201d<\/strong>, published in the <strong><em>Civil Engineering Journal<\/em><\/strong> on <strong>13 June 2023<\/strong>, investigated how the amount of concrete surrounding a GFRP bar affects its bond with concrete. The researchers conducted 18 pull-out tests to understand how different bonding conditions influence bond strength, slip, and failure.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Why use GFRP in the first place? Unlike conventional steel reinforcement, GFRP is resistant to corrosion. This makes it attractive for structures exposed to aggressive environments, such as coastal infrastructure, bridges, and other structures where moisture and corrosive substances can threaten steel reinforcement. The corrosion resistance of GFRP may also allow engineers to consider smaller concrete covers in some applications. However, reducing the surrounding concrete can create another problem: weaker bonding.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The researchers examined three conditions. The first used GFRP bars surrounded by concrete cover. The second placed the bars without the same concrete cover, while the third combined the GFRP bars with a complete GFRP sheet wrapping. The researchers then compared their bond stress\u2013slip behavior and failure patterns.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"530\" height=\"651\" src=\"https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-4.png\" alt=\"\" class=\"wp-image-4206\" srcset=\"https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-4.png 530w, https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-4-244x300.png 244w\" sizes=\"(max-width: 530px) 100vw, 530px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The results were striking. Removing the concrete cover caused the bond strength to decrease by <strong>65%<\/strong>. This demonstrates that concrete surrounding a reinforcement bar does much more than simply protect it from the environment\u2014it also contributes significantly to transferring forces between the bar and the concrete.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">There was, however, an encouraging finding. Adding a complete GFRP sheet increased the bonding stress by <strong>26.4%<\/strong> compared with the corresponding condition without the sheet. The researchers also identified different failure mechanisms, including bar pull-out, concrete crushing, and GFRP-sheet debonding.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">These findings matter beyond the laboratory. Bridges, buildings, and other infrastructure need reinforcement that can reliably transfer forces throughout their service life. A material may be strong on its own, but that strength is not enough if it cannot effectively work together with concrete.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The study supports <strong>Sustainable Development Goal 3 (SDG 3): Good Health and Well-Being<\/strong>, because dependable reinforcement bonding contributes to the safety and reliability of structures used by communities. It also supports <strong>Sustainable Development Goal 11 (SDG 11): Sustainable Cities and Communities<\/strong>, as corrosion-resistant reinforcement and improved strengthening techniques may help extend the service life and resilience of existing and future infrastructure.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The lesson is simple: structural strength is not only about strong materials. It is also about how well those materials work together. In reinforced concrete, the bond between GFRP and concrete may be invisible\u2014but it can make a very visible difference in whether a structure performs safely.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Reference:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">DOI: https:\/\/doi.org\/10.28991\/CEJ-SP2023-09-010<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Contact:<br>Prof. Rudy Djamaluddin<br>+62-811-4666-10<br>rudy0011@gmail.com<\/p>\n","protected":false},"excerpt":{"rendered":"<p>GOWA, Indonesia Jun 03 2026\/SMSRG\/ \u2013\u00a0When we look at a reinforced concrete beam, we usually notice the concrete and the reinforcement bars. But there is an invisible connection between them that is just as important: bond. Bond allows forces to move from the concrete into the reinforcement and back again. Without sufficient bond, a reinforcement [&hellip;]<\/p>\n","protected":false},"author":74,"featured_media":4206,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","_themeisle_gutenberg_block_has_review":false,"footnotes":""},"categories":[50],"tags":[43,35],"class_list":["post-4205","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-research-project","tag-sdg11","tag-sdg3"],"acf":[],"uagb_featured_image_src":{"full":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-4.png",530,651,false],"thumbnail":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-4-150x150.png",150,150,true],"medium":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-4-244x300.png",244,300,true],"medium_large":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-4.png",530,651,false],"large":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-4.png",530,651,false],"1536x1536":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-4.png",530,651,false],"2048x2048":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-4.png",530,651,false]},"uagb_author_info":{"display_name":"adminsmsrg","author_link":"https:\/\/trg.unhas.ac.id\/smsrg\/author\/adminsmsrg\/"},"uagb_comment_info":0,"uagb_excerpt":"GOWA, Indonesia Jun 03 2026\/SMSRG\/ \u2013\u00a0When we look at a reinforced concrete beam, we usually notice the concrete and the reinforcement bars. But there is an invisible connection between them that is just as important: bond. Bond allows forces to move from the concrete into the reinforcement and back again. Without sufficient bond, a reinforcement&hellip;","rttpg_featured_image_url":{"full":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-4.png",530,651,false],"landscape":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-4.png",530,651,false],"portraits":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-4.png",530,651,false],"thumbnail":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-4-150x150.png",150,150,true],"medium":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-4-244x300.png",244,300,true],"large":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-4.png",530,651,false],"1536x1536":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-4.png",530,651,false],"2048x2048":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-4.png",530,651,false]},"rttpg_author":{"display_name":"adminsmsrg","author_link":"https:\/\/trg.unhas.ac.id\/smsrg\/author\/adminsmsrg\/"},"rttpg_comment":0,"rttpg_category":"<a href=\"https:\/\/trg.unhas.ac.id\/smsrg\/category\/research-project\/\" rel=\"category tag\">Research Project<\/a>","rttpg_excerpt":"GOWA, Indonesia Jun 03 2026\/SMSRG\/ \u2013\u00a0When we look at a reinforced concrete beam, we usually notice the concrete and the reinforcement bars. But there is an invisible connection between them that is just as important: bond. Bond allows forces to move from the concrete into the reinforcement and back again. Without sufficient bond, a reinforcement&hellip;","_links":{"self":[{"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/posts\/4205","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/users\/74"}],"replies":[{"embeddable":true,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/comments?post=4205"}],"version-history":[{"count":2,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/posts\/4205\/revisions"}],"predecessor-version":[{"id":4289,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/posts\/4205\/revisions\/4289"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/media\/4206"}],"wp:attachment":[{"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/media?parent=4205"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/categories?post=4205"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/tags?post=4205"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}