{"id":4202,"date":"2026-06-03T23:19:30","date_gmt":"2026-06-03T15:19:30","guid":{"rendered":"https:\/\/trg.unhas.ac.id\/smsrg\/?p=4202"},"modified":"2026-08-19T06:00:20","modified_gmt":"2026-08-18T22:00:20","slug":"saving-aging-concrete-giving-damaged-beams-a-second-life","status":"publish","type":"post","link":"https:\/\/trg.unhas.ac.id\/smsrg\/saving-aging-concrete-giving-damaged-beams-a-second-life\/","title":{"rendered":"Saving Aging Concrete: Giving Damaged Beams a Second Life"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">GOWA, Indonesia Jun 03 2026\/SMSRG\/ \u2013\u00a0A reinforced concrete beam may look solid and dependable, but its real strength depends on what happens beneath the surface. When concrete begins to break away and the steel reinforcement inside can become exposed. Once exposed to moisture and other aggressive environmental conditions, the steel may corrode, weakening the very system designed to carry the load.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">But does spalling always mean that a concrete beam must be replaced?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A study titled <strong>\u201c<em>Study of Post-Spalling Reinforced Concrete Beam Repair Using Grouting and GFRP Reinforcement<\/em>\u201d<\/strong>, published in the <strong><em>Civil Engineering Journal<\/em><\/strong> on <strong>01 January 2024<\/strong>, explored how damaged reinforced concrete beams could be repaired using grouting and Glass Fiber Reinforced Polymer (GFRP) reinforcement. The research examined not only how much load the repaired beams could carry, but also their cracking, ductility, and ability to absorb energy.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The researchers tested twelve reinforced concrete beams. Three served as control specimens, three were repaired using Sikagrout-215 mortar, and six were strengthened with GFRP using different reinforcement configurations. All specimens were subjected to four-point bending tests, allowing the researchers to observe how the beams behaved as the applied load increased.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The findings provide an important warning about conventional repair. <strong>Grouting alone actually decreased the beam&#8217;s load capacity.<\/strong> In other words, filling the damaged area and restoring the concrete cover did not automatically restore the beam&#8217;s original structural performance. A repair that looks successful from the outside may therefore still leave important structural weaknesses behind.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1015\" height=\"751\" src=\"https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-3.png\" alt=\"\" class=\"wp-image-4203\" srcset=\"https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-3.png 1015w, https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-3-300x222.png 300w, https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-3-768x568.png 768w\" sizes=\"(max-width: 1015px) 100vw, 1015px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The results became more encouraging when GFRP was introduced. The combination of mortar grouting and GFRP increased the maximum load compared with grouting alone. Strengthening the support region also helped restore the beam&#8217;s function by <strong>9.3%<\/strong>. Among the tested reinforcement arrangements, the BGRST configuration produced significant improvements in first-crack behavior, yielding response, and ultimate performance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Another interesting observation was what happened after failure. Beams reinforced with Sikagrout-215 experienced fractures more frequently, while GFRP composites provided partial protection of the beam&#8217;s load-carrying capacity after fracture. This suggests that GFRP can do more than simply increase strength\u2014it can also influence how a damaged beam behaves when it approaches failure.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Why does this matter outside the laboratory? Spalling can affect bridges, buildings, parking structures, and other infrastructure found in cities and communities. Replacing an entire structure because of localized deterioration can be expensive, disruptive, and resource-intensive. Effective repair and strengthening can potentially extend the service life of existing infrastructure, provided that engineers properly assess the damage before selecting a repair method.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This research supports <strong>Sustainable Development Goal 3 (SDG 3): Good Health and Well-Being<\/strong>, because maintaining structural safety helps protect the people who use buildings and infrastructure every day. It also contributes to <strong>Sustainable Development Goal 11 (SDG 11): Sustainable Cities and Communities<\/strong>, because maintaining and rehabilitating existing infrastructure can help cities become safer, more resilient, and more sustainable.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The lesson is clear: repairing spalled concrete is not simply about putting the concrete back. The structure&#8217;s ability to carry loads must also be restored and verified. With careful assessment, appropriate grouting, and effective GFRP strengthening, a damaged beam may have more than a repair\u2014it may have a renewed structural life.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Reference:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">DOI: https:\/\/doi.org\/10.28991\/CEJ-2024-010-01-08<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Contact:<br>Prof. Rudy Djamaluddin<br>+62-811-4666-10<br>rudy0011@gmail.com<\/p>\n","protected":false},"excerpt":{"rendered":"<p>GOWA, Indonesia Jun 03 2026\/SMSRG\/ \u2013\u00a0A reinforced concrete beam may look solid and dependable, but its real strength depends on what happens beneath the surface. When concrete begins to break away and the steel reinforcement inside can become exposed. Once exposed to moisture and other aggressive environmental conditions, the steel may corrode, weakening the very [&hellip;]<\/p>\n","protected":false},"author":74,"featured_media":4203,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","_themeisle_gutenberg_block_has_review":false,"footnotes":""},"categories":[50],"tags":[43,35],"class_list":["post-4202","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-research-project","tag-sdg11","tag-sdg3"],"acf":[],"uagb_featured_image_src":{"full":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-3.png",1015,751,false],"thumbnail":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-3-150x150.png",150,150,true],"medium":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-3-300x222.png",300,222,true],"medium_large":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-3-768x568.png",768,568,true],"large":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-3.png",1015,751,false],"1536x1536":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-3.png",1015,751,false],"2048x2048":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-3.png",1015,751,false]},"uagb_author_info":{"display_name":"adminsmsrg","author_link":"https:\/\/trg.unhas.ac.id\/smsrg\/author\/adminsmsrg\/"},"uagb_comment_info":0,"uagb_excerpt":"GOWA, Indonesia Jun 03 2026\/SMSRG\/ \u2013\u00a0A reinforced concrete beam may look solid and dependable, but its real strength depends on what happens beneath the surface. When concrete begins to break away and the steel reinforcement inside can become exposed. Once exposed to moisture and other aggressive environmental conditions, the steel may corrode, weakening the very&hellip;","rttpg_featured_image_url":{"full":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-3.png",1015,751,false],"landscape":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-3.png",1015,751,false],"portraits":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-3.png",1015,751,false],"thumbnail":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-3-150x150.png",150,150,true],"medium":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-3-300x222.png",300,222,true],"large":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-3.png",1015,751,false],"1536x1536":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-3.png",1015,751,false],"2048x2048":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2026\/08\/image-3.png",1015,751,false]},"rttpg_author":{"display_name":"adminsmsrg","author_link":"https:\/\/trg.unhas.ac.id\/smsrg\/author\/adminsmsrg\/"},"rttpg_comment":0,"rttpg_category":"<a href=\"https:\/\/trg.unhas.ac.id\/smsrg\/category\/research-project\/\" rel=\"category tag\">Research Project<\/a>","rttpg_excerpt":"GOWA, Indonesia Jun 03 2026\/SMSRG\/ \u2013\u00a0A reinforced concrete beam may look solid and dependable, but its real strength depends on what happens beneath the surface. When concrete begins to break away and the steel reinforcement inside can become exposed. Once exposed to moisture and other aggressive environmental conditions, the steel may corrode, weakening the very&hellip;","_links":{"self":[{"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/posts\/4202","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/users\/74"}],"replies":[{"embeddable":true,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/comments?post=4202"}],"version-history":[{"count":2,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/posts\/4202\/revisions"}],"predecessor-version":[{"id":4290,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/posts\/4202\/revisions\/4290"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/media\/4203"}],"wp:attachment":[{"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/media?parent=4202"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/categories?post=4202"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/tags?post=4202"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}