{"id":4052,"date":"2025-04-21T03:35:53","date_gmt":"2025-04-20T19:35:53","guid":{"rendered":"https:\/\/trg.unhas.ac.id\/smsrg\/?p=4052"},"modified":"2025-04-21T03:39:00","modified_gmt":"2025-04-20T19:39:00","slug":"static-loading-test-on-box-culvert-at-the-structural-and-materials-laboratory-department-of-civil-engineering-hasanuddin-university","status":"publish","type":"post","link":"https:\/\/trg.unhas.ac.id\/smsrg\/static-loading-test-on-box-culvert-at-the-structural-and-materials-laboratory-department-of-civil-engineering-hasanuddin-university\/","title":{"rendered":"Static Loading Test on Box Culvert at the Structural and Materials Laboratory, Department of Civil Engineering, Hasanuddin University"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">This study focuses on the static loading test conducted on a box culvert at the Structural and Materials Laboratory, Department of Civil Engineering, Hasanuddin University. The test aims to evaluate the structural performance and load-bearing capacity of the box culvert under controlled laboratory conditions. By applying a gradually increasing static load, the test simulates real-life loading scenarios to observe deflection behavior, stress distribution, and overall structural integrity. The results of this test provide valuable insights for assessing the safety, durability, and design adequacy of precast concrete culverts used in infrastructure projects.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>This study focuses on the static loading test conducted on a box culvert at the Structural and Materials Laboratory, Department of Civil Engineering, Hasanuddin University. The test aims to evaluate the structural performance and load-bearing capacity of the box culvert under controlled laboratory conditions. By applying a gradually increasing static load, the test simulates real-life [&hellip;]<\/p>\n","protected":false},"author":74,"featured_media":4055,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","_themeisle_gutenberg_block_has_review":false,"footnotes":""},"categories":[27,26],"tags":[],"class_list":["post-4052","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-activities","category-news"],"acf":[],"uagb_featured_image_src":{"full":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2025\/04\/box.png",3024,3005,false],"thumbnail":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2025\/04\/box-150x150.png",150,150,true],"medium":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2025\/04\/box-300x298.png",300,298,true],"medium_large":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2025\/04\/box-768x763.png",768,763,true],"large":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2025\/04\/box-1024x1018.png",1024,1018,true],"1536x1536":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2025\/04\/box-1536x1526.png",1536,1526,true],"2048x2048":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2025\/04\/box-2048x2035.png",2048,2035,true]},"uagb_author_info":{"display_name":"adminsmsrg","author_link":"https:\/\/trg.unhas.ac.id\/smsrg\/author\/adminsmsrg\/"},"uagb_comment_info":0,"uagb_excerpt":"This study focuses on the static loading test conducted on a box culvert at the Structural and Materials Laboratory, Department of Civil Engineering, Hasanuddin University. The test aims to evaluate the structural performance and load-bearing capacity of the box culvert under controlled laboratory conditions. By applying a gradually increasing static load, the test simulates real-life&hellip;","rttpg_featured_image_url":{"full":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2025\/04\/box.png",3024,3005,false],"landscape":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2025\/04\/box.png",3024,3005,false],"portraits":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2025\/04\/box.png",3024,3005,false],"thumbnail":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2025\/04\/box-150x150.png",150,150,true],"medium":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2025\/04\/box-300x298.png",300,298,true],"large":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2025\/04\/box-1024x1018.png",1024,1018,true],"1536x1536":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2025\/04\/box-1536x1526.png",1536,1526,true],"2048x2048":["https:\/\/trg.unhas.ac.id\/smsrg\/wp-content\/uploads\/sites\/95\/2025\/04\/box-2048x2035.png",2048,2035,true]},"rttpg_author":{"display_name":"adminsmsrg","author_link":"https:\/\/trg.unhas.ac.id\/smsrg\/author\/adminsmsrg\/"},"rttpg_comment":0,"rttpg_category":"<a href=\"https:\/\/trg.unhas.ac.id\/smsrg\/category\/activities\/\" rel=\"category tag\">Activities<\/a> <a href=\"https:\/\/trg.unhas.ac.id\/smsrg\/category\/news\/\" rel=\"category tag\">News<\/a>","rttpg_excerpt":"This study focuses on the static loading test conducted on a box culvert at the Structural and Materials Laboratory, Department of Civil Engineering, Hasanuddin University. The test aims to evaluate the structural performance and load-bearing capacity of the box culvert under controlled laboratory conditions. By applying a gradually increasing static load, the test simulates real-life&hellip;","_links":{"self":[{"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/posts\/4052","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/users\/74"}],"replies":[{"embeddable":true,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/comments?post=4052"}],"version-history":[{"count":1,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/posts\/4052\/revisions"}],"predecessor-version":[{"id":4054,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/posts\/4052\/revisions\/4054"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/media\/4055"}],"wp:attachment":[{"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/media?parent=4052"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/categories?post=4052"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/trg.unhas.ac.id\/smsrg\/wp-json\/wp\/v2\/tags?post=4052"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}